Freezing Temperatures

In Texas, the winter season is generally mild with few extreme weather events. However, it is important to prepare for the possibility of a sudden and severe cold front. Homes and businesses in Texas, particularly in Houston, may not be equipped to withstand a hard freeze. As a result, we would like to remind you of the potential damage that can occur to your pipes during such events. Furthermore, we would like to take this opportunity to inform you of the measures we take to protect your facilities and ensure they continue to operate smoothly during such conditions.

Freezing Temperatures Versus a Hard Freeze

When temperatures fall below 32 degrees Fahrenheit, it is considered freezing. Typically, short periods of freezing temperatures do not result in damage to pipes or facilities. However, when temperatures fall below 30 degrees Fahrenheit for more than eight hours, it is classified as a hard freeze. During a hard freeze, the water in exposed lines and irrigation backflow preventers freezes, which can cause damage to equipment and instrumentation in the water and wastewater facilities.

It is important to note that as water freezes, it expands, which can lead to broken pipes, water loss, and costly repairs. In addition, there may be secondary expenses such as replacing damaged carpet, flooring, sheetrock, furniture, and other possessions. Furthermore, galvanized pipes may not burst during a freeze, but expansion can cause the galvanizing to separate from the pipe and create an area for corrosion to start, which can ultimately result in leaks.

To ensure the protection and uninterrupted operation of our customers’ facilities during a hard freeze, we take a number of preventative measures. We closely monitor weather reports, drain lines, and turn off water to outdoor faucets and other exposed areas. We also educate our customers on how to prepare for a hard freeze and what steps they can take to minimize the risk of damage to their facilities.

How Do I Prepare My Home?

  • All garden hoses should be disconnected from the outside spigots. If you forget and do not drain them, do not move them during freezing temperatures. They may be brittle and crack.
  • All exposed water pipes and outside spigots should be wrapped or covered and then taped. Most home improvement stores have tape, foam wrapping and other products for this purpose. Purchase supplies early as they usually sell out quickly when a hard freeze is coming.
  • Wrap pipes in the attic, especially if they are under an eave leading into the house. While they are not exposed to the outside, they can freeze quickly.
  • All lids on your water meter boxes should be securely closed to keep freezing winds out.
  • If you have an irrigation system, turn off the water to the system at your backflow preventer and then drain the system. Wrap the backflow preventer as well.
  • Start your preparations early while supplies are easier to find!

There are various methods and materials that can be utilized to prevent freeze damage, including foam and fiberglass insulation sized for specific pipes and secured with vinyl and plastic tape, prefabricated spigot covers, spray foam insulation, heat tape, heat lamps, and portable heaters. These items can usually be found at building supply stores, but it is not recommended to wait until the last minute as they may sell out quickly. If supplies are unavailable, improvising with towels and duct tape to insulate vulnerable areas can be an alternative. Turning off the water and draining the lines is the most reliable way to prevent freeze damage, which should always be done for backflow preventers and irrigation systems. However, turning off the water is not an option for those who need potable water inside their homes. To prevent water from expanding and breaking pipes during a freeze, it is best practice to periodically flush the lines through all fixtures inside the house. Space heaters, heat lamps, and heat tape can be used for small areas directly exposed to freezing temperatures, but caution should be exercised when using devices with extension cords.

When and Where Do I Prepare for a Freeze?

Preparing adequately for a winter freeze is imperative, given the high potential for costly damage and loss. Ensuring that preventative measures are in good condition throughout the winter is the best practice. In the event of a cold front, it is crucial to monitor the weather regularly to determine its arrival time, the anticipated temperature, and the duration of sub-freezing temperatures. By staying vigilant and well-prepared, we can minimize the risk of damage and loss resulting from a winter freeze.

How Does Inframark Prepare?

When it comes to protecting vital components, water and wastewater facilities are no different than your home, but a plant failure can have much higher consequences. At Inframark, we take a comprehensive approach to preparing for winter, considering the WHAT, WHEN, WHERE, and HOW of our facilities. In the fall, we conduct Freeze Protection Audits to assess the most vulnerable components of the system and develop a plan to ensure their protection. The following items are just some of the components wrapped and insulated:

  • Above ground valves
  • Sensor lines
  • Sight glasses for hydropneumatic tanks
  • Backflow preventers
  • Blow off valves
  • Chemical feed lines
  • Drip oilers for wells
  • All exposed water lines
  • Heaters in exposed control rooms and cabinets

Inframark’s objective is to complete the winterization process by October, ensuring that all vulnerable components have been wrapped and insulated to prevent freezing damage. The Operator conducts a freeze protection audit and submits it to their manager, who then walks the site with the Operator to confirm that all potential freezing hazards have been addressed. Taking proactive measures to prevent freeze damage is far more cost-effective than dealing with the consequences after the fact. It is essential to winterize all susceptible areas, ensuring a safe winter season.

We hope that this winter will not see a serious hard freeze, but if we do, Inframark is ready.

Drought Contingency Plan Stage 1 – Voluntary Water-Use Restrictions

Due to prolonged drought conditions and North Fort Bend Water Authority’s initiation of Stage 1 of its Drought Contingency Plan (“DCP”), Fort Bend MUD 118 (the “District”) has instituted Stage 1 water conservation measures of its DCP. Effective immediately, the following voluntary water-use restrictions are in place:

  1. All outdoor water usage will be limited to
    1. even-numbered [calendar] days for customers with even-numbered addresses
    2. odd-numbered [calendar] days for water customers with odd-numbered addresses
    3. Outdoor water use is prohibited between the hours of 6:00 a.m. and 10:00 a.m. and between the hours of 6:00 p.m. and 12:00 a.m. (midnight) [on the designated days of outdoor water use]
  1. Water customers are asked to voluntarily reduce water use by
    1. checking your toilets, showerheads, and faucets for leaks
    2. checking under sinks for wet spots, leaking supply lines, fittings, or valves
    3. checking your irrigation system for leaks, repairing as needed
    4. sweep driveways, sidewalks, and patios instead of hosing them off

The Board of Directors of Fort Bend MUD 118 appreciates your cooperation to help conserve one of our community’s most important resources. Please stay alert to District communication as drought conditions improve or worsen.

Request to Voluntarily Reduce Water Usage

Fort Bend MUD 118 and the North Fort Bend Water Authority (NFBWA) continue to monitor the impacts of this freeze event and are anticipating a reduction in surface water delivery from the City of Houston. Fort Bend MUD 118 and the NFBWA request your assistance by voluntarily reducing water usage. Please conserve water as much as possible as we navigate this weather event.

No Boil Water Notice for FBMUD 118

There is no boil water notice in effect for Fort Bend County Municipal Utility District No. 118 residents or businesses. The City of Houston has issued a Boil Water Notice for their water system and other systems effected by the City’s issue. While local media (and social media) are reporting boil water notices for the City and those other Water Districts in our area, these notices do not pertain to Fort Bend County Municipal Utility District No. 118 receivers, as the District maintains independent water production facilities. Again, Fort Bend County Municipal Utility District No. 118 is not currently under a Boil Water Notice.

In the event a Boil Water Notice needs to be issued for our community, notification will be provided. For immediate and up-to-date 24/7 information, you can always reach out to EDP’s 24-hour Customer Service line at (832) 467-1599.